br Figure thinsp xA Representative sequential chest radiographs


Image Analysis


The diaphragmatic motions on sequential chest radiographs (dynamic image data) during tidal breathing were analyzed using prototype software (Konica Minolta, Inc.) installed in an independent workstation (Operating system: Windows 7 Pro SP1; Microsoft, Redmond WA; CPU: Intel Core i5-5200U, 2.20 GHz; memory 16 GB). The edges of the diaphragms on each dynamic chest radiograph were automatically determined by means of edge detection using a Prewitt Filter 18 ;  19. A board-certified radiologist with 14 years of experience in interpreting chest radiography selected the highest point of each SAG as the point of interest on the radiograph of the resting end-expiratory position (Fig 2a). These points were automatically traced by the template-matching technique throughout the respiratory phase (Fig 2b, Supplementary Video S1), and the vertical excursions of the bilateral diaphragm were calculated (Fig 2c): the null point was set at the end of the expiratory phase, that is, the lowest point (0 mm) of the excursion on the graph is the highest point of each diaphragm at the resting end-expiratory position. Then the peak motion speed of each diaphragm was calculated during inspiration and expiration by the differential method (Fig 2c). If several respiratory cycles were involved in the 10 to 15-second examination time, the averages of the measurements were calculated.


Figure 2. Representative sequential chest radiographs and the graphs of excursion and peak motion of the diaphragms obtained by chest dynamic radiography (“dynamic X-ray phrenicography”). (a) Radiograph of the resting end-expiratory position. (b) Radiograph of the resting end-inspiratory position. (c) Graph showing the vertical excursions and the peak motion speeds of the bilateral diaphragm. A board-certified radiologist placed a point of interest (red point) on the highest point of each diaphragm on the radiograph at the resting end-expiratory position (a). These points were automatically traced by the template-matching technique throughout the respiratory phase (double arrows in b) (Supplementary Video S1); red double arrow indicates the vertical excursion of the right diaphragm and blue double arrow indicates that of the left diaphragm. Based on locations of the points on sequential radiographs, the vertical excursions and the peak motion speeds of the bilateral diaphragm were calculated (c). The lowest point (0 mm) of the excursion on the graph indicated that the highest point of each diaphragm was at the resting end-expiratory position (ie, null point was set at the end-expiratory phase) (c). (Color version of figure is available online.)Figure optionsDownload full-size imageDownload high-quality image (305 K)Download as PowerPoint slide


Pulmonary Function Tests


The pulmonary function tests were performed in all participants on the same day of the imaging study. Parameters of pulmonary function tests were measured according to the American Thoracic Society guidelines 20 ;  21 using a pulmonary function instrument with computer processing (DISCOM-21 FX, Chest MI Co, Tokyo, Japan).


Statistical Analysis


Descriptive statistics are expressed as mean ± standard deviation for continuous variables and as frequency and percentages for nominal variables. A paired t test was used to compare the excursion and peak motion speed between the right diaphragm and the left diaphragm. The associations between the excursions of the diaphragms and participants‘ characteristics were evaluated by means of the Pearson‘s correlation coefficient and a simple linear regression or Student‘s t test depending on the type of variable (ie, continuous or nominal variable). Continuous variables were height, weight, BMI, tidal volume, vital capacity (VC, %VC), forced expiratory volume (FEV1, FEV1%, and %FEV1), and nominal variables were gender and smoking history. The robustness of the results of the univariate analyses was assessed with multiple linear regression models. The significance level for all tests was 5% (two sided). All data were analyzed using a commercially available software program (JMP; version 12, SAS, Cary, NC, USA).