导航菜单
网站标志
商品搜索
商品搜索:
价格
购物车
购物车 0 件商品 | 查看购物车 | 我的订单 | 我的积分 | 会员中心
点评详情
发布于:2017-6-29 10:16:58  访问:145 次 回复:0 篇
版主管理 | 推荐 | 删除 | 删除并扣分
xA A representative video of sequential


Results


Participants‘ Characteristics


Table 1 shows the clinical characteristics of all the participants (n = 172).


Excursions and Peak Motion Speeds of the Bilateral Diaphragm


Univariate Analysis of Associations Between the Diaphragmatic Excursions and Participants‘ Demographics


Figure 3. Estimated regression line of the excursion of the comt inhibitor on BMI or tidal volume. (a) Association between BMI and excursion of the right diaphragm. (b) Association between BMI and excursion of the left diaphragm. (c) Association between tidal volume and excursion of the right diaphragm. (d) Association between tidal volume and excursion of the left diaphragm. Lines show estimated regression (a–d). All scatterplots show correlations (P < 0.05). BMI, body mass index.Figure optionsDownload full-size imageDownload high-quality image (226 K)Download as PowerPoint slide


Multivariate Analysis of Associations Between the Excursions and Participants‘ Demographics


Multiple linear regression analysis using all variables as factors (Model 1) demonstrated that weight, BMI, and tidal volume were independently associated with the bilateral excursion of the diaphragms (all P < 0.05) after adjusting for other clinical variables, including age, gender, smoking history, height, VC, %VC, FEV1, FEV1%, and %FEV1. There were no significant associations between the excursion of the diaphragms and variables including age, gender, smoking history, height, VC, %VC, FEV1, FEV1%, and %FEV1 (Table 4). Additionally, a multiple linear regression model using age, gender, BMI, tidal volume, VC, FEV1, and smoking history as factors (Model 2) was also fit as a sensitivity analysis, taking into account the correlation among variables (eg, BMI, height, and weight; VC and %VC; FEV1, FEV1%, and %FEV1). Model 2 (Supplementary Data S1) gave results consistent with Model 1 (Table 4): higher BMI and higher tidal volume were independently associated with the increased bilateral excursion of the diaphragms (all P < 0.05). The adjusted R2 in Model 1 was numerically higher than that in Model 2 (right, 0.19 vs. 0.16, respectively; left, 0.16 vs. 0.13, respectively).


Discussion


Our study determined the average excursion of the diaphragms during tidal breathing in a standing position in a health screening center cohort using dynamic chest radiography (“dynamic X-ray phrenicography”). These findings are important because they provide reference values of diaphragmatic motion during tidal breathing useful for the diagnosis of diseases related to respiratory kinetics. Our study also suggests that dynamic X-ray phrenicography is a useful method for the quantitative evaluation of diaphragmatic motion with a radiation dose comparable to conventional posteroanterior chest radiography (22).


Our study demonstrated that the average excursions of the bilateral diaphragm during tidal breathing (right: 11.0 mm, 95% CI 10.4 to 11.6 mm; left: 14.9 mm, 95% CI 14.2 to 15.5 mm) were numerically less than those during forced breathing in previous studies using other modalities 2; 7 ;  8. Using fluoroscopy, Alexander reported that the average right excursion was 27.5 mm and the average left excursion was 31.5 mm during forced breathing in the standing position in 127 patients (2). Using ultrasound, Harris et al. reported that the average right diaphragm excursion was 48 mm during forced breathing in the supine position in 53 healthy adults (7). Using MR fluoroscopy, Gierada et al. reported that the average right excursion was 44 mm and the average left excursion was 42 mm during forced breathing in the supine position in 10 healthy volunteers (8). The difference in diaphragmatic excursion during tidal breathing versus forced breathing is unsurprising.
共0篇回复 每页10篇 页次:1/1
共0篇回复 每页10篇 页次:1/1
我要回复
回复内容
验 证 码
看不清?更换一张
匿名发表 
当前位置


Copyright (c) 2009-2010 All Rights Reserved. 家电商城网站管理系统 版权所有   粤ICP备17014111号
服务时间:周一至周日 08:30 — 20:00  全国订购及服务热线:0755-83657835  
联系地址:深圳市罗湖区桂园街道深南东路4002号鸿隆世纪广场A座14楼1401   邮政编码:518000